International Journal of Advanced Technology and Engineering Exploration (IJATEE) ISSN (Print): 2394-5443 ISSN (Online): 2394-7454 Volume - 11 Issue - 120 November - 2024

  1. Google Scholar
Developmental study of a 3D prosthetic foot using finite element analysis

Noor B. Mohammed and Yassr Y. Kahtan

Abstract

The most popular type of prosthetic foot is the energy storage and return (ESAR) foot, which provides stability and balance during gait. The study focuses on the development of an ESAR prosthetic foot using various types of acrylonitrile butadiene styrene (ABS) material. The primary aim was to enhance stability and balance during gait. Two strategies were implemented: modifying the material to improve its mechanical properties and altering the foot design. The findings revealed that design changes were more critical to the model's success than material adjustments. Finite element analysis (FEA) was used to compare the stress responses of ABS, carbon fiber polylactic acid (PLA), and polyethylene terephthalate glycol (PETG) during gait cycles. During the heel strike (HS) phase, stress values were measured as follows: ABS Plus at 11.562 MPa, carbon fiber PLA at 11.723 MPa, and PETG at 1.9806 MPa. Notably, the total deformation was less for carbon fiber PLA and PETG compared to ABS Plus, with values recorded at 1.9671 mm, 1.7445 mm, and 0.55776 mm, respectively. The most successful design iteration (design F) demonstrated optimal results with a total deformation of 4.7254 mm, strain energy of 0.1863 mJ, and von Mises stress of 19.57 MPa, achieving a safety factor of 1.584 overall. Conversely, other designs, particularly design E, exhibited high stress levels (42.816 MPa) and safety factors below the acceptable threshold of 1.5. Dynamic analysis showed poor performance under fatigue testing, with safety factors ranging from 1.0368e-7 to 8.9274e-8 indicating a high risk of structural failure. Overall, the study highlights the critical need for effective design modifications in prosthetic foot development to ensure safety and functionality for amputees.

Keyword

Energy store and return, Finite element analysis, Prosthetic foot, Stress and deformation, Carbon fiber, Gait cycle.

Cite this article

Mohammed NB, Kahtan YY.Developmental study of a 3D prosthetic foot using finite element analysis. International Journal of Advanced Technology and Engineering Exploration. 2024;11(120):1592-1612. DOI:10.19101/IJATEE.2024.111100971

Refference

[1]Pană CF, Manta LF, Vladu IC, Cismaru ȘI, Petcu FL, Cojocaru D, et al. The design of a smart lower-limb prosthesis supporting people with transtibial amputation-a data acquisition system. Applied Sciences. 2022; 12(13):1-18.

[2]Kim J, Wensman J, Colabianchi N, Gates DH. The influence of powered prostheses on user perspectives, metabolics, and activity: a randomized crossover trial. Journal of Neuroengineering and Rehabilitation. 2021; 18:1-3.

[3]Houdijk H, Wezenberg D, Hak L, Cutti AG. Energy storing and return prosthetic feet improve step length symmetry while preserving margins of stability in persons with transtibial amputation. Journal of Neuro Engineering and Rehabilitation. 2018; 15:1-8.

[4]Ehara Y, Beppu M, Nomura S, Kunimi Y, Takahashi S. Energy storing property of so-called energy-storing prosthetic feet. Archives of Physical Medicine and Rehabilitation. 1993; 74(1):68-72.

[5]Park JW, Greenspan B, Tabb T, Gallo E, Danielescu A. 3D printed energy return elements for upper limb sports prosthetics. Prosthesis. 2023; 5(1):13-34.

[6]Bowen J, Hausselle J, Gonzalez R. A low-cost customizable prosthetic foot with energy return capabilities. Prosthetics and Orthotics Open Journal. 2018; 2(1).

[7]Childers WL, Takahashi KZ. Increasing prosthetic foot energy return affects whole-body mechanics during walking on level ground and slopes. Scientific Reports. 2018; 8(1):1-12.

[8]Tuteski O, Kočov A. The application of additive manufacturing in developing 3D printed prostethics and orthotic devices. Industry 4.0. 2020; 5(1):23-6.

[9]Faustini MC, Neptune RR, Crawford RH, Stanhope SJ. Manufacture of passive dynamic ankle–foot orthoses using selective laser sintering. IEEE Transactions on Biomedical Engineering. 2008; 55(2):784-90.

[10]Gibson KS, Woodburn J, Porter D, Telfer S. Functionally optimized orthoses for early rheumatoid arthritis foot disease: a study of mechanisms and patient experience. Arthritis Care & Research. 2014; 66(10):1456-64.

[11]Kucewicz M, Baranowski P, Małachowski J, Popławski A, Płatek P. Modelling, and characterization of 3D printed cellular structures. Materials & Design. 2018; 142:177-89.

[12]Tack P, Victor J, Gemmel P, Annemans L. 3D-printing techniques in a medical setting: a systematic literature review. Biomedical Engineering Online. 2016; 15:1-21.

[13]Tao Z, Ahn HJ, Lian C, Lee KH, Lee CH. Design and optimization of prosthetic foot by using polylactic acid 3D printing. Journal of Mechanical Science and Technology. 2017; 31:2393-8.

[14]Rochlitz B, Pammer D. Design and analysis of 3D printable foot prosthesis. Periodica Polytechnica Mechanical Engineering. 2017; 61(4):282-7.

[15]Segal AD, Zelik KE, Klute GK, Morgenroth DC, Hahn ME, Orendurff MS, et al. The effects of a controlled energy storage and return prototype prosthetic foot on transtibial amputee ambulation. Human Movement Science. 2012; 31(4):918-31.

[16]Ray SF, Wurdeman SR, Takahashi KZ. Prosthetic energy return during walking increases after 3 weeks of adaptation to a new device. Journal of Neuroengineering and Rehabilitation. 2018; 15:1-8.

[17]Hamzah M, Gatta A. Design of a novel carbon-fiber ankle-foot prosthetic using finite element modeling. In conference series: materials science and engineering 2018 (pp. 1-15). IOP Publishing.

[18]Song Y, Choi S, Kim S, Roh J, Park J, Park SH, et al. Performance test for laminated-type prosthetic foot with composite plates. International Journal of Precision Engineering and Manufacturing. 2019; 20:1777-86.

[19]Womac ND, Neptune RR, Klute GK. Stiffness and energy storage characteristics of energy storage and return prosthetic feet. Prosthetics and Orthotics International. 2019; 43(3):266-75.

[20]Catto E. Realization and evaluation of a prosthetic foot multibody model in quasi-static and dynamic conditions. Doctoral Dissertation, Politecnico Di Torino. 2019.

[21]Tryggvason H, Starker F, Lecomte C, Jonsdottir F. Use of dynamic FEA for design modification and energy analysis of a variable stiffness prosthetic foot. Applied Sciences. 2020; 10(2):1-12.

[22]Kamel H, Harraz O, Azab K, Attia T. Developing an optimized low-cost transtibial energy storage and release prosthetic foot using three-dimensional printing. Journal of Engineering and Science in Medical Diagnostics and Therapy. 2020; 3(2):021103.

[23]Ali MM. Design and analysis of a non-articulated prosthetic foot for people of special needs. Doctoral Dissertation, Thesis in Mechanical Engineering. AL-Nahrain University. 2010.

[24]Maitland ME, Allyn KJ, Ficanha E, Colvin JM, Wernke MM. Finite element simulation of prosthetic foot adaptation to mediolateral-angled cross-slopes. JPO: Journal of Prosthetics and Orthotics. 2020; 32(4):236-44.

[25]Quraishi HA, Shepherd MK, Mcmanus L, Harlaar J, Plettenburg DH, Rouse EJ. A passive mechanism for decoupling energy storage and return in ankle–foot prostheses: a case study in recycling collision energy. Wearable Technologies. 2021; 2:1-13.

[26]Rajput S, Burde H, Singh US, Kajaria H, Bhagchandani RK. Optimization of prosthetic leg using generative design and compliant mechanism. Materials Today: Proceedings. 2021; 46:8708-15.

[27]Tabucol J, Brugo TM, Povolo M, Leopaldi M, Oddsson M, Carloni R, et al. Structural fea-based design and functionality verification methodology of energy-storing-and-releasing prosthetic feet. Applied Sciences. 2021; 12(1):1-26.

[28]Hameed MI, Ali AA. Finite element design and manufacturing of a woven carbon fiber prosthetic foot. Association of Arab Universities Journal of Engineering Sciences. 2022; 29(2):9-18.

[29]Major MJ, Twiste M, Kenney LP, Howard D. Amputee independent prosthesis properties-a new model for description and measurement. Journal of Biomechanics. 2011; 44(14):2572-5.

[30]Budynas RG, Nisbett JK. Shigleys mechanical engineering design. New York: McGraw-Hill; 2015.

[31]Yu T, Zhang Z, Song S, Bai Y, Wu D. Tensile and flexural behaviors of additively manufactured continuous carbon fiber-reinforced polymer composites. Composite Structures. 2019; 225:111147.

[32]Ferreira RT, Amatte IC, Dutra TA, Bürger D. Experimental characterization and micrography of 3D printed PLA and PLA reinforced with short carbon fibers. Composites Part B: Engineering. 2017; 124:88-100.

[33]Kannan S, Ramamoorthy M, Sudhagar E, Gunji B. Mechanical characterization and vibrational analysis of 3D printed PETG and PETG reinforced with short carbon fiber. In AIP conference proceedings 2020. AIP Publishing.

[34]Kabir SF, Mathur K, Seyam AF. A critical review on 3D printed continuous fiber-reinforced composites: history, mechanism, materials and properties. Composite Structures. 2020; 232:111476.

[35]Padzi MM, Bazin MM, Muhamad WM. Fatigue characteristics of 3D printed acrylonitrile butadiene styrene (ABS). In conference series: materials science and engineering 2017 (pp. 1-6). IOP Publishing.

[36]Kadry S, El HA. Numerical methods for reliability and safety assessment. Springer; 2015.

[37]Mohammed NB, Kahtan YY. Development, analysis and manufacture of a prosthetic carbon fiber foot model. In conference proceedings 2024. AIP Publishing.